Power Distribution Cables
600/1000V Single conductor Type T/N distribution cables
Construction
Conductor:Stranded copper conductor tin or alloy coated where necessary for the application , conductor per
ASTM or IEC 60228.
Separator tape: optional
Insulation: Polyvinylchloride(PVC)/nylon according to IEEE 1580 2010 Type T/N,Type X, E, T, S, P, LSX and LSE
as option.
Shielding: optional
Jacket: Thermosetting Polychloroprene(neoprene) according to IEEE 1580 2010 Type N, Type T, CP, CPE, L, P or
TPO jacket as option (optional for Type P with HD thicknesses).
Armor: optional and shall be nonmagnetic
Sheath:
Thermosetting Polychloroprene(neoprene) according to IEEE 1580 2010 Type N, Type T, CP, CPE, L, P or TPO
sheath as option (optional except for tinned copper braid armoured cables).
Optional: For halogen-free constructions, Type LSX, LSE or LSS insulation shall be used with a Type L or TPO
jacket/sheath.
Table B.3—Typical dimensions and weights; single-, two-, three-, and four-conductor 600/1000 V; Type T/N distribution cables
Number of conductors |
AWG /kcmil | Unarmored | Armored | Armored and sheathed | |||
---|---|---|---|---|---|---|---|
Nom. dia. (in) | Approx. weight (lb/1000 ft) | Nom. dia. (in) | Approx. weight (lb/1000 ft) | Nom. dia. (in) | Approx. weight (lb/1000 ft) | ||
1 |
14 | 0.21 | 31 | 0.27 | 44 | 0.37 | 74 |
1 |
12 | 0.23 | 41 | 0.29 | 54 | 0.39 | 87 |
1 |
10 | 0.26 | 58 | 0.32 | 74 | 0.42 | 110 |
1 |
8 | 0.32 | 90 | 0.38 | 108 | 0.48 | 149 |
1 |
6 | 0.34 | 123 | 0.4 | 141 | 0.5 | 184 |
1 |
4 | 0.42 | 188 | 0.48 | 212 | 0.61 | 280 |
1 |
1 | 0.58 | 364 | 0.64 | 395 | 0.76 | 476 |
1 |
1/0 | 0.63 | 440 | 0.69 | 473 | 0.81 | 560 |
1 |
2/0 | 0.67 | 536 | 0.73 | 571 | 0.89 | 696 |
1 |
3/0 | 0.73 | 653 | 0.79 | 690 | 0.95 | 824 |
1 |
4/0 | 0.79 | 801 | 0.85 | 841 | 1.01 | 985 |
1 |
250 | 0.89 | 977 | 0.95 | 1022 | 1.12 | 1192 |
1 |
300 | 0.96 | 1163 | 1.02 | 1213 | 1.19 | 1394 |
1 |
350 | 1 | 1315 | 1.06 | 1365 | 1.23 | 1553 |
1 |
400 | 1.05 | 1505 | 1.11 | 1558 | 1.28 | 1753 |
1 |
500 | 1.13 | 1811 | 1.19 | 1867 | 1.36 | 2076 |
1 |
600 | 1.24 | 2225 | 1.3 | 2290 | 1.47 | 2517 |
1 |
750 | 1.34 | 2686 | 1.4 | 2757 | 1.57 | 3001 |
1 |
1000 | 1.49 | 3530 | 1.55 | 3608 | 1.78 | 3978 |
NOTE—These values are for reference purposes only and should not be construed as requirements. Dimensions are based on the use of Class B conductors. Weights of armored constructions are based on aluminum braid armor. It is recommended that the user/specifier contact the manuf acturer for manufacturer specific values.